1.Fiber loss at the operating wavelength
Cable Length | 2.0 | 2.0 | ||
Fiber Type | Multimode | Singlemode | ||
Wavelength (nm) | 850 | 1300 | 1310 | 1550 |
Fiber Atten. dB/km | 3 [3.5] | 1 [1.5] | 0.4 [1/0.5] | 0.3 [1/0.5] |
Total Fiber Loss | 6.0 [7.0] | 2.0 [3.0] |
2.Connector Loss
Multimode connectors losses of 0.2-0.5 dB. Singlemode connectors losses of 0.1-0.2 dB. Max allowable 0.75
3.Splice Loss
0.1-0.5 dB for multimode splices, 0.3 for singlemode fiber less than 0.05 dB
those are the basic for fiber link budget, for more accuracy there also need to take account of-
Add the fiber loss, connector and splice losses to get the link loss. Data From Manufacturer's Specification and
Loss Margin Calculation
Dynamic Range (dB) (above) | 15 | 15 |
Cable plant Link Loss (dB) | 3.8 (Typ) | 7.05 (TIA) |
Link Loss Margin (dB) | 11.2 | 7.95 |